| Height |
3' 6-1/2" from auditorium floor to lip
of pit cover |
| Proscenium Opening |
54' x 25'-11-1/4" (wxh)(Height 23'9"
with valance) |
| Depth |
45' (plaster line to wall), add 12' with pit cover
|
| Wing Space |
24' SL 20'SR |
| Loading Access |
3 loading doors, 2 w/dock levelers & 1 with
van access.
Each have 8'x10' door openings.
|
| Counterweights |
78,500 lbs.
|
| #of Line Sets |
68 -- See schedule for details
|
| Grid Height |
72' |
| Batten Height |
67' (Travel) 71' (High Trim) 47'3" (Orch. shell clearance) |
| Battens |
70 lines - 1.5"x70' pipes (1400 lbs. Max.
- single prch) |
| Power |
(3)--400amp, 3 phase, 3 leg, 120v/208v (stage left)
200 amp, 3 phase for sound, 120v/208v (stage right)
(2)--60amp, 3 phase for shore power
|
| Convenience Receptacles |
(5)--30amp convenience receptacles at grid iron
(4)--30amp receptacles at F.O.H. rigging points |
| Pit |
8'6" x 46'4" x 6'4"(wxlxd)
Pit has three positions: Pit, Seating and Stage Levels.
Pit is Not Hydraulic- Takes 5 hands 1 hour to adjust. |
| Backstage Elevator Door |
6'x7' opening |
| Proscenium Rigging |
8 Points, 7 and 23 feet off center; the first set approximately 2'6" DS of the plaster line, and the other set 5'6" DS of the plaster line.
2000 lbs weight limit per point |
| Offstage Rooms |
8 DRESSING ROOMS
3 Principal Rooms on Stage Level
2 Principal Rooms in Lower Level
3 Private Rooms in Lower Level
2 CHORUS ROOMS in lower level
Women's Accommodates 27
Men's Accommodates 24
1 HAIR/WARDROBE ROOM 30'X18' in lower level
1 CATERING ROOM in lower level |
| Sound |
Basic PA system - Great for lecutures. |
| Lighting |
4 Super Trouper Follow Spots - located in spot booth in back of third balcony; 208v/20a power
ETC Insight 3 System, (48) Pars, (16) 36-degree Source 4,
(26) 26-degree Source 4, (58) 19-degree Source 4,
(10) 5-degree Source 4, (10)Triple Cyc |
| Risers |
All 4X8- Five at 8"
Five at 16"
Two at 32"
|
| Smoking Policy |
The Morris Performing Arts Center is a non-smoking
facility. |
| Decibal Level Policy |
The City of South Bend has designated that events
at this facility not exceed 95db. Please call for more information. |
| Website |